NYKR(AL)Y 1 x (16-800) mm² 0.6/1 kV

Cu / PVC / LS / PVC / AWA / PVC
(Copper Conductor, PVC Insulated, Lead Sheathed, Aluminium Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1

Application

For indoors, outdoors, in ground and in duct.
Mainly on chemical industries, refineries, petrol
stations and any other locations where that is a
risk that solvent, fuel and other chemicals may
penetrate and high pulling stresses may occur
during installation and operation.


Special Features on Request :
• Fire Resistance
• Oil Resistance
• UV Resistance
• Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
• Heat Resistance
• Anti Termite
• Anti Rodent
• Low Smoke Zero Halogen


Note :
Conductor Shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 800 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape

Standard Packing
16 - 185 sqmm supplied in wooden drum @ 1000 m
240 - 800 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%

Construction Data

Nom. Cross Section Area Overall Diameter Cable Weight
approx.
approx.
mm²
mm
kg/km
16
23.0 1,210
25
23.0 1,280
35
23.0 1,359
50
25.0 1,645
70
27.0 1,958
95
29.5 2,430
120
31.0 2,784
150
33.0 3,183
185
36.0 3,859
240
40.0 4,894
300
43.5 5,824
400
48.0 7,196
500 53.5 8,815
630 58.5 10,889
800 64.0 13,240

Electrical Data

Conductor Inductance Current - Carrying Capacity at 30° C * Short circuit current at 1 sec
Nom. Cross Section Area
DC Resistance at 20°C
AC Resistance at 70°C
Trefoil formation
Flat formation
in air in ground in air in ground
(mm²)
Max. (Ω/km)
Max. (Ω/km)
(mH/km) (mH/km) Max. (A) Max. (A) Max. (A) Max. (A) Max. (kA)
16
1.15 1.376 0.489 0.535 102 99 105 101 1.84
25
0.727 0.870 0.440 0.486 134 128 137 131 2.88
35
0.524 0.627 0.410 0.456 162 154 166 158 4.03
50
0.387 0.463 0.392 0.438 197 183 201 187 5.75
70
0.268 0.321 0.371 0.417 245 223 250 227 8.05
95
0.193 0.232 0.358 0.404 298 265 303 269 10.93
120
0.153 0.184 0.347 0.393 342 299 347 303 13.80
150
0.124 0.149 0.339 0.385 386 333 392 336 17.25
185
0.0991 0.120 0.331 0.378 441 372 445 374 21.28
240
0.0754 0.092 0.326 0.372 513 420 513 418 27.60
300
0.0601 0.074 0.321 0.367 578 464 575 458 34.50
400
0.0470 0.059 0.317 0.363 651 510 643 499 41.20
500 0.0366 0.048 0.313 0.359 722 549 708 533 51.50
630 0.0283 0.039 0.303 0.350 801 593 781 572 64.89
800 0.0221 0.032 0.298 0.344 874 632 849 607 82.40

*Further information about rating factor for certain cable arrangement can be found on supplementary technical information