NA2XSEKBY 3 x (25-300) mm² 3.6/6 kV

Al / XLPE / CTS / PVC / LS / PVC / DSTA / PVC
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Lead Sheathed, Double Galvanized Steel Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502-2

Application

For indoor, outdoor, in ground and in duct.
Mainly on chemical industries, refineries, petrol
stations and any other locations where there is
a risk that solvent, fuel and other chemicals may
penetrate and low mechanical damage may
occur.

Special Features on Request :
• Oil Resistance
• UV Resistance
• Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
• Anti Termite
• Anti Rodent
• Low Smoke Zero Halogen


Note :
Conductor Shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape

Standard Packing
25 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%

Construction Data

Nom. Cross Section Area Overall Diameter Cable Weight
approx.
approx.
mm²
mm
kg/km
25 43.5 4,100
35 46.5 4,716
50 50.0 5,373
70 54.5 6,361
95 59.0 7,358
120 63.0 8,361
150 66.5 9,312
185 71.0 10,614
240 77.0 12,366
300 85.5 15,450

Electrical Data

Conductor Inductance Current - Carrying Capacity at 30° C * Short circuit current at 1 sec
Nom. Cross Section Area
DC Resistance at 20°C
AC Resistance at 90°C
in air in ground Conductor Screen
(mm²)
Max. (Ω/km)
Max. (Ω/km)
(mH/km) Max. (A) Max. (A) Max. (kA) Max. (kA)
25 1.20 1.539 0.346 118 112 2.35 1.03
35 0.868 1.113 0.326 143 134 3.29 1.03
50 0.641 0.822 0.314 170 158 4.70 1.03
70 0.443 0.568 0.296 212 193 6.58 1.03
95 0.320 0.411 0.284 256 230 8.93 1.03
120 0.253 0.325 0.276 294 261 11.28 1.03
150 0.206 0.265 0.269 332 291 14.10 1.03
185 0.164 0.212 0.262 380 329 17.39 1.03
240 0.125 0.162 0.256 443 378 22.56 1.37
300 0.100 0.130 0.253 502 422 28.20 1.37

*Further information about rating factor for certain cable arrangement can be found on supplementary technical information