K Type Thermocouple Extension Cable
KXYY (1-50) Pairs x 1.5 mm2 300 V

(Chromel-Alumel Conductor, PVC Insulated, Individual or Collective Screen, PVC Sheathed)
Standard Specification : IEC 60584, ANSI MC 96.1

Application

For transmission of thermoelectric voltage from measuring junction to reference junction.

Special Features on Request :
• Oil Resistance
• UV Resistance
• Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
• Heat Resistance
• Anti Termite
• Anti Rodent
• Low Smoke Zero Halogen
• Nylon Coated


Fig. 01 : Collective Screen

Fig. 02 : Individual Screen

Note :
Conductor Shape
All construction supplied in solid (re) or circular stranded (rm)

Standard Packing
All conductor supplied in wooden drum @ 1000 m
Length tolerance per drum ± 2%
Size of drain wire : 0.5 mm²

Construction Data

No.
of
pairs
Size
1.5 mm2
Collective Screen Individual Screen
Overall
Diameter

Cable
Weight
Overall
Diameter
Cable
Weight
approx.
approx. approx. approx.
mm
kg/km
mm
kg/km
1 9.9 137 - -
2 12.8 199 14.6 313
3 14.9 243 15.5 359
4 16.7 302 16.9 423
5 18.3 386 18.5 427
6 19.7 431 21.5 529
7 21.0 474 21.5 542
9 23.5 584 25.5 685
10 25.0 650 27.5 766
12 27.0 759 30.0 899
14 29.0 879 31.5 1,035
15 30.0 959 33.5 1,127
16 30.5 1,012 35.0 1,202
18 32.5 1,107 37.5 1,321
19 33.0 1,160 37.5 1,378
20 34.0 1,255 39.5 1,554
24 37.0 1,457 46.5 1,775
30 41.0 1,793 49.5 2,161
36 45.0 2,150 54.0 2,591
40 47.5 2,360 56.0 2,839
48 51.5 2,823 63.0 3,413
50 52.5 2,928 64.5 3,541

Material & Color Code

Type KX
Material ( + )
Chromel
( - ) Alumel
Limit of Error -
(Temp. Range)
IEC 60584 Class 1
µ 1.5 °C / µ 60 ØV ( -25 ~ 200 °C)
Class 2 µ 2.5 °C / µ 100 ØV ( -25 ~ 200 °C)
ANSI MC - 96.1
µ 2.2 °C ( 0 ~ 200 °C )
Color Code Insulation ( + )
Yellow
( - ) Red
Jacket Yellow

Electrical Data

Conductor AC
Normal
Cross
Section
Nominal Value
Loop Resistance
at 20 °C
Voltage
Test
mm2
/km volt/1 min.
1.5 680 1000